Acceptance Tests¶
Conditions (all tests)¶
| Machine | V3 prototype, calibration of 2026-11-17, settings as committed on 2026-11-18 (config.toml, printer.cfg) |
| Board | Test PCB (Software/Slicer/tests/fixtures/Test PCB/), top side, held in the PCB mounts |
| Job | jobs/Test PCB-top-0603.job.json: 23 x 0603 resistors |
| Parts | 0603 resistors on 8 mm paper tape in feeder F1 |
| Tip | N08 (board touch Z 39.5, inspect Z 34.6) |
| Air | compressor ~60 psi |
| Room | indoor lab, normal ceiling light; machine lights as configured (frame strip 15 %) |
| Operator steps allowed | load the board, load tape, Vision home, Start; answer dialogs |
Requirements and tests¶
| # | Requirement | Test | Pass criterion |
|---|---|---|---|
| 1 | Operate without a laptop or network: start, stop, jog, home, choose a program on an HMI | load a job from an SD card / USB stick and run it using only the touchscreen | job loaded, started, watched, stopped from the screen |
| 2 | Vision identifies passes and fails correctly | every up-camera decision (PASS / REJECT / EMPTY) and every board-check decision (PLACED / MISSING) over the runs, judged by a person from the saved photo (human_agrees column) |
≥ 95 % correct out of ≥ 100 |
| 3 | Pick 0603/0805 parts from tape | picks that came up with a good part / all picks, from the event log (report) |
≥ 95 % |
| 4 | Feeder runs without failures | consecutive 23-part runs from F1 | runs complete; each miss logged and retried |
| 5 | 500 components per hour | seconds per part over a full job, timed by run-job (alignment excluded) |
≥ 500 CPH (≤ 7.2 s/part) |
| 6 | Placement accuracy (characterised) | check-board after each run: offset of each part from its pads |
reported (mean, worst) |
| 7 | Continuous operation | four 23-part runs back to back without repair, re-calibration or reboot | all complete |
Procedure¶
- Daily startup. Load tape in F1. Empty the reject bin.
- Put a bare Test PCB on the plate.
- Touchscreen -> Job -> Test PCB-top-0603, Align first on -> Start.
- When done, run
python -m pnpvision check-board "jobs/Test PCB-top-0603.job.json". - Replace the board, repeat for the next run.
- After the last run:
python -m pnpvision report --out report_latest. - Fill in
human_agreesinvision_review.csvandplacement_review.csvby looking at each photo; count the agreements. - Back up
pnp_events.sqlite,report_latest/andresults/.
Results: Results.