Skip to content

Testing and Troubleshooting

Feeder cycle test

Picks from a feeder and drops the part in the reject bin, N times, without vision. It measures the feeder and the pick on their own:

python -m pnpvision feeder-cycle F1 --n 20

It reports how many picks came up with a part. Each try is logged, so report includes it.

Problems

Symptom Check
Servo doesn't move FEEDER_SET SLOT=1 ANGLE=45; servo 5 V supply on; its ground joined to the Uno; signal on D5
Servo buzzes at rest normal only during a stroke; after FEEDER_TOGGLE it should go limp. Narrow the pulse widths in pnp_feeders.cfg if it buzzes at 0° or 180°
Tape doesn't advance far enough reel drags; lever not reaching the next hole: raise that slot's stroke angle (variable_stroke_angles) by 5 - 15°
Tape advances, but the pick is empty part bounced out: keep the plain 400/400 ms stroke; check the cover tape is peeled back far enough
Part picked off-centre every time re-teach the pick spot
Servo gets hot or slips stripped gears: replace the servo
Error about a missing [servo feeder_N] that slot isn't configured (or is commented out) in pnp_feeders.cfg