Recovery Check¶
Use this when the head was removed, the nozzle swapped, the gantry used for something else, or anything bumped.
- Nozzle empty, Vision home done,
UP_LIGHT_ON. - Touchscreen Pick & Place -> Calibration check, or:
python -m pnpvision check-machine - It checks that
printer.cfgstill has the pnpvision sections, that the homing dot sits on the crosshair, that both camera maps still predict a small jog, and that the nozzle bore is where the up camera expects. Each line says OK or REDO with the step to repeat.
Don't trust check-machine --apply blindly
--apply assumes the nozzle moved and shifts the camera offset to match. If the up
camera moved instead (or a light washed out the bore), it saves a wrong offset: on 11-17 it
added a bad +0.47 mm in Y. To fix the offset, measure it directly with
calibrate-offset, then check with a dry run.
Placements all shifted the same way?¶
Before changing any calibration:
- Re-align the board (Job page with Align first on, or
align-board). A stale board position is the most common cause. - Do a dry run and look at the photos in
job_<time>/: the crosshair marks the target, and the down camera sees about 59 px per mm. - Only then look at the camera offset.