Skip to content

How It Works

The OSHE Pick and Place is an open-source hardware project of the Open Source Hardware Enterprise (oshe.io) at Michigan Tech.

The machine moves a single vacuum nozzle over a fixed plate. The board sits on the plate, the tape feeders sit at the front, and two cameras tell the software exactly where everything is.

Front view of the V3 machine
Front view: tape comes up from the reels into the three feeders on the front rail; the touchscreen is on the right.

The parts of the machine

Subsystem What it is
Frame Ender 3 aluminum extrusion with 3D-printed legs and corners
Motion CoreXY (two motors share X and Y through crossed belts), Z for nozzle height, a small stepper to turn the nozzle
Toolhead LumenPnP-style holder for Samsung CP40 nozzle tips, NEMA 11 rotation motor, down camera, LEDs
Staging plate Printed tiles holding the PCB mounts, the camera datum (reference grid), the reject bin and the up camera
Cameras Down camera on the toolhead (finds the board, checks placed parts), up camera under the plate (checks the part on the nozzle)
Feeders 0816-style tape feeders, each advanced by a hobby servo driven by an Arduino Uno
Pneumatics Compressor and solenoid valve for the nozzle vacuum
Electronics BTT Octopus Pro (motion), Arduino Uno (servos, lights), Raspberry Pi 4 (host), 7" touchscreen

The software

Program Runs on Job
pnpslice your computer (Windows app or Python) Reads a KiCad board, checks it, orders the parts, writes the job file
Klipper Pi + Octopus Pro + Uno Motion, steppers, servos, lights, G-code macros
Moonraker / Mainsail Pi Web API and web dashboard
KlipperScreen Pi (touchscreen) The machine's own screen, including the PnP Job page
crowsnest Pi Streams both cameras
pnpvision Pi Calibration, visual homing, board alignment, the job runner, logging and reports

One part, step by step

  1. Feed: the servo advances the tape by one pocket.
  2. Pick: the nozzle drops onto the part and the vacuum switches on.
  3. Inspect: the nozzle stops over the up camera. pnpvision measures the part's size, offset and angle. A wrong part, an empty nozzle, a part on its side or upside down is rejected.
  4. Correct and place: the nozzle turns to the right angle, moves to the board position plus the measured offset, lowers, releases the vacuum and lifts.
  5. Rejected parts go to the reject bin and the machine tries again (up to 3 picks).

Before the first part, the machine finds the board: the down camera visits the alignment pads chosen by pnpslice and fits the board's exact position and rotation.

Z runs upside down

Z = 0 is the top. A larger Z moves the nozzle lower. The nozzle touches the plate at about Z 50 and the top of a PCB at about Z 39.5.