Nozzle Tips¶
The toolhead takes Samsung CP40 nozzle tips. They pull straight off and push on.
| Tip | Approx. bore | Used for |
|---|---|---|
| N045 | 0.45 mm | 0201 |
| N08 | 0.8 mm | 0402, 0603, 0805 (default) |
| N14 | 1.4 mm | 1206 |
| N24 | 2.4 mm | SOIC-8 |
| N400, N750 | 4.0, 7.5 mm | larger parts |
Changing a tip¶
- Lift the nozzle (Z 20), switch the vacuum off.
- Pull the old tip off straight down; push the new one on until it seats.
- If this tip was used before:
python -m pnpvision tip N14 --current. - If it is a new tip: record its heights (Tip heights),
then centre the up camera on it (
calibrate-motion --cam up --center-only). - Run the Recovery Check if the holder was touched.
A job that needs a different tip asks you to swap it, then re-centres by itself.
A bent or clogged tip
shows up as parts picked off-centre or "empty" pickups with the part still in the pocket. Look at
an up-camera photo of the empty tip (snapshot --cam up --lit): the bore should be a clean dark
circle.