Safety¶
The machine moves fast (up to 400 mm/s in a job), runs on 24 V and uses compressed air. Read this page before you power it on.
Emergency stop¶
How to stop the machine immediately
Tap EMERGENCY STOP on the touchscreen. It is:
- on the PnP Job page whenever a job runs (next to Continue and Stop job), and
- in the Pick & Place menu at all times.
Mainsail (browser) has the same button in its top bar. All three send Klipper's emergency stop
(M112): every motor and output stops at once, the vacuum turns off and the part drops.
To recover: FIRMWARE_RESTART (Mainsail console or touchscreen), then Vision home.
The emergency stop is a software stop: it relies on the Pi and Klipper running. For a hard stop, switch off the power supply. A hardware emergency-stop switch in the 24 V line is a planned upgrade (Roadmap).
Stop job (on the Job page) is the gentle stop: the job ends cleanly after the current part. It needs two taps so it can't be hit by accident.
Hearing: wear protection during extended use
The compressor and the venturi's exhaust are loud, and during a job the vacuum switches on and off every few seconds. Noise above 85 dBA over a working day can cause permanent hearing loss (NIOSH recommended limit: 85 dBA averaged over 8 hours; every +3 dB halves the safe time). Wear ear plugs or ear muffs during long runs, and whenever the level at your position is above 85 dBA. Measure it with a sound-level meter app (for example the free NIOSH SLM app) at the operator's position. Keep the compressor away from where people stand, and fit a silencer (muffler) on the venturi's exhaust port.
Hazards and how they are handled¶
Approach: ISO 12100 style. For each hazard, first design it out, then guard or limit it, then warn.
| Hazard | Where | Mitigation |
|---|---|---|
| Moving gantry (impact, pinch) | X/Y belts, carriage, corners | Belts run in extrusion slots; motor current limited (1.0 A X/Y); travel limits in Klipper and pnpvision; red JOB RUNNING banner on the touchscreen; emergency stop |
| Nozzle moving down | toolhead | Z speed capped at 50 mm/s in Klipper; Z range limited to 0 - 51 mm; pnpvision lifts to a safe height before any X/Y move |
| Unexpected motion after power loss | whole machine | Klipper needs homing after every power-up; a job never resumes by itself |
| Unexpected motion from the network | whole machine | Moonraker trusts the local network: connect it only to a network you trust; a running job blocks other machine buttons |
| Electrical (24 V, mains supply) | electronics enclosure | Electronics enclosed; 24 V line fused; switch off and unplug before opening |
| Compressed air (about 60 psi) | compressor, tubing, valve, venturi | The valve closes on power loss or any Klipper fault (shutdown_value: 0); switch the compressor off and bleed the line before disconnecting tubing |
| Noise (hearing) | compressor, venturi exhaust | compressor placed away from the operator; silencer on the venturi exhaust; hearing protection for extended use or above 85 dBA |
| Heat | stepper drivers | No heaters on the machine; drivers run at 0.5 - 1.0 A, well below the TMC5160 limits; board fan output (FAN0) |
| Small parts | reject bin, feeders | 0603/0805 parts are tiny: keep the reject bin emptied and away from children |
Rules for operating¶
- Keep hands out of the work area while the JOB RUNNING banner is shown.
- Don't jog or run other macros while a job runs: the job moves the machine itself (other PnP buttons refuse to start).
- Before jogging by hand, lift the nozzle to Z 30 or higher (a smaller number) - the reject bin (15 mm), datum (11 mm) and PCB mounts (8 - 10 mm) stick up from the plate.
- Switch off and unplug the supply before maintenance; switch off the compressor and bleed the air.
- Wear hearing protection (ear plugs or muffs) during extended runs; for a short job near a quiet compressor it is optional - measure if unsure.
- Use eye protection when working on pressurized tubing. No other PPE is needed.
After an emergency stop¶
- Make sure nothing is caught or jammed. Remove any loose part from the board.
FIRMWARE_RESTART.- Vision home (the touchscreen menu), then restart the job. Parts already placed stay placed:
use the job's
--onlyoption or a smaller job for the rest.