Skip to content

3. Nozzle and Up Camera

The nozzle working over the up camera's ring light during a job (real speed).

6. Up-camera map and centre

The up camera has to know exactly where the nozzle axis is in its image.

  1. UP_LIGHT_ON. Move the nozzle (empty, N08 tip) over the up camera at safe Z, then lower it until the tip is sharp - not the holder face. With a part on the tip, the part's bottom is sharp at about Z 34.6; that is the calibration plane.
  2. Tune the detector without moving: python -m pnpvision find-dot --cam up --polarity dark --thresh 40 --rmin 8 --rmax 30 (the bore of the tip shows as a dark circle).
  3. Map and centre:
    python -m pnpvision calibrate-motion --cam up --find-center --step 1 --polarity dark --thresh 40 --rmin 8 --rmax 30
    
    Steps over ~1 mm fail (the tip's side wall hides the bore).

7. Down camera to nozzle offset

How far the down camera's centre is from the nozzle. Measured by eye on datum dot 0:

python -m pnpvision calibrate-offset

Lower the nozzle onto the dot centre by eye when asked; do it 3 times. Ours: (9.183, 52.927) mm, spread ±0.04 mm.

8. Tip heights

For each nozzle tip, record where it touches the bare board and where a part on it is in focus over the up camera:

python -m pnpvision tip N08 --board-touch-z 39.5 --inspect-z 34.6 --current

Find the touch Z by jogging down in 0.1 mm steps onto a bare PCB until a paper slip just drags.

9. Rotation direction

With a part on the nozzle over the up camera, turn in 30° steps and inspect (inspect-up). If the measured angle goes the wrong way, flip [rotation] direction in config.toml.

10. Placement check

Put spare parts on a bare board, pick and place them, and measure where they land with the down camera:

python -m pnpvision place-test           # then --correct to check