Calibration ties the two cameras to the machine's coordinates, so that what a camera sees can be reached by the nozzle to a few hundredths of a millimetre. Do it once per machine, in this order. Each step says when it has to be redone.
All commands run on the Pi from ~/OSHE-PnP/Software/pnpvision as
~/venv-pnp/bin/python -m pnpvision <command>. Results are saved in calibration/machine.json.
| # | Step | Command | Redo when |
|---|---|---|---|
| 1 | Lens calibration (both cameras) | calib_capture.py, then check-lens |
lens refocused or swapped |
| 2 | Exposure and lighting | snapshot, focus-sweep |
camera, light or lens changed |
| 3 | Down-camera motion map | calibrate-motion --cam down --step 3 |
camera moved or refocused |
| 4 | Visual homing | home --teach |
datum or down camera moved (then redo all below) |
| 5 | Datum reference | datum --teach, datum --reference |
datum moved |
| 6 | Up-camera map and centre | calibrate-motion --cam up --find-center |
up camera moved or refocused |
| 7 | Down camera to nozzle offset | calibrate-offset |
camera or nozzle holder moved |
| 8 | Tip heights | tip N08 --board-touch-z ... --inspect-z ... |
tip changed |
| 9 | Rotation direction | inspect-up |
rotation motor or tip changed |
| 10 | Placement check | place-test |
nozzle, head or a camera moved |
| 11 | Reject bin | teach-bin --goto |
bin moved |
| 12 | Feeders | teach-feeder F1 ... |
feeder moved |
After that, the board is found automatically before every job (Run a Job). If anything gets bumped later, use the Recovery Check.
Measured on the prototype (2026-11-17)¶
| Value | Result |
|---|---|
| Repeatability (down camera, go away and back) | about 0.01 mm |
| Datum fit | rms 0.039 mm |
| Down camera to nozzle offset | (9.183, 52.927) mm |
| N08 tip: board touch Z / inspect Z | 39.5 / 34.6 |
| Down camera scale | about 59 px/mm at PCB height |
Lessons that cost us hours
- Calibration targets must not move. A loose paper dot slid 0.05 mm during fast moves and looked like a machine error. Tape or glue it.
- Centre a feature before measuring it. The down camera is only 11.5 mm from the board; its scale changes about 9 % per mm of height.
- The up camera is tilted ~5°. Calibrate and inspect at one fixed height (the part-bottom plane, Z 34.6 for the N08 tip). Inspecting at the holder face read a fake 0.4 mm offset.
- Use square pixels when undistorting. OpenCV's default made round dots 24 % oval.
- Use