5. Pneumatics

The nozzle vacuum comes from compressed air: a small compressor feeds a solenoid valve, and the valve drives a venturi vacuum generator connected to the toolhead's rotary fitting.

compressor (auto-cycling, ~60 psi) -> solenoid valve (Octopus FAN1, PD12)
    -> venturi vacuum generator -> tubing -> rotary fitting -> CP40 nozzle tip
Step Check
Mount the compressor away from the work area it vibrates; the machine must not move with it
Run tubing to the toolhead with a service loop the toolhead travels the whole plate: no pulling at any corner
Wire the valve to FAN1 VALVE_ON / VALVE_OFF in the Mainsail console click the valve
Test the vacuum VALVE_ON, cover the tip with a finger: you should feel suction; a 0603 should jump to the tip

pnpvision switches the valve itself: vacuum on 150 ms before lifting at the pick, off 200 ms before lifting at the place (config.toml [run] vac_ms / release_ms).

Noise

Mount the compressor away from where the operator stands (on a soft pad to cut vibration) and fit a silencer on the venturi's exhaust port. Even so, wear hearing protection during long runs: see Safety.

Ongoing

Compressor, valve and venturi part numbers and the regulator setting are being added to the V3 BOM.

Before disconnecting any tubing

Switch the compressor off and open the valve (VALVE_ON) to bleed the pressure.